- Concrete & Cementitious Surfaces
- Pavers / Brick / Clay Brick
- Travertine
- Limestone
- Slate Surfaces
- All Light Commercial
- Loading Docks and Ramps
- Parking Structures
- Marine Piers & Pilings
- Multi-Family Housing
- Theme & Water Parks
- Healthcare & Educational
- Government & Historical
- Industrial & Business Parks
- Warehousing Flooring
Applying TK-290 Series Penetrate Salt and Water Repellent
Preparation:
Before using this product, read the Safety Data Sheet for complete safety information.
All surfaces to be treated must be clean and structurally sound. Thoroughly clean surfaces to remove all grease, oils, form oils, or other contaminants. Best results are obtained by applying TK-TRI-SILOXANE 290 (290 VOC) to dry surfaces. It is recommended that surface temperatures be 40°F or above at the time of application to ensure that surfaces are frost-free.
Existing Concrete Preparation:
Remove unsound concrete and repair cracks or deteriorated areas prior to application. Surfaces may require manual abrasion to achieve maximum penetration.
New Concrete Preparation:
Water cure fresh concrete. As a standard procedure, allow new concrete to thoroughly cure (typically 14 to 28 days) before applying this product.
A test patch should always be performed to determine proper results and coverage rates prior to application.
Mixing:
The material is ready for use and requires no mixing. It is unlawful to further dilute with non-exempt solvents.
Application:
Apply by roller or spray equipment in a uniform manner and in sufficient quantity to completely wet out the substrate with a minimum of 2-inch run down. The recommended coverage rate for most concrete substrates is 125 square feet per gallon. Very porous surfaces may require two coats.